Medical Regulator Oxygen Humidifier and Flowmeter
Basic Info
Model No.: CR-666
Product Description
Model NO.: CR-666 Type: Gas Regulator Brand Name: Carong Stock: Rich Application: Hospital Color: Green Quality: Good Group: Adult Trademark: CaRong or OEM Origin: China Certification: CE, FDA, ISO13485 Feature: Repetition Sample: Free Exporter Markets: Global MOQ: 10000PCS Quality Guarantee Period: 5 Years LCD Display: Without LCD Display Function: Oxygen Humidification Specification: CE, SGS HS Code: 9018 Product Description:
Oxygen flowmeter with humidifier bottle is used in connection with gas outlets through quick adaptor, probe or pin index. It can be connected with adaptors of different types, such as French standard AFNOR, British standard, German standard DIN, American standard Ohmeda or Japanese standard.
Oxygen inhalator with humidifier
Usage: Medical care, hospital
Input pressure: 0-25MPa
Oulet pressure: 0-0.3 MPa
Flow: 0-15L/min
Connection: G5/8
Body material: Excellent brass
Medical Oxygen Regulator The flowmeter with humidifier is used in reducing gas pressure and adjusting the gas volume, which rescue patient and treat as oxygen therapy by hospital. Also may make using of other gas reduced pressure and the control flow. Product main feature: The product has artistic outlook, and flow control comfortable and stable. The reductor is adjustable; The structure is unique, and the performance is reliable. The stainless steel floater and the orange substrate flowmeter have a especially visual effect; The international standard connect way, is suitable for all kinds of gas bottle installation. Range of application Give oxygen for first-aid or oxygen uptake for the people who are lack of oxygen.
How to use
1. Open the valve of oxygen cylinder after connect the screw nut of air intake closely.
2. Connect the oxygen pipe to the oxygen outlet firmly.
3. Demount the humidifying cup(anti clock wise rotation), put some distilled water in (purified water or plain boiled water can also take place), the water quantity should be between the bottom and top tick mark, then tighten up the bottle cap to the humidifying cup(clockwise rotation).
4. Rotate the flow regulating valve to the rate you need (anti clockwise to up, clockwise to down, till to close), then put it to nose to use.
5. Close the valve of oxygen cylinder firstly while not using, then close the flow regulating valve until the pointer of oxygen manometer return to zero.
Attention
1. Make sure there is no ash on the connector and check the screw thread, then install the inhalator.
2. Make sure the flow meter is vertical to the floor and flow regulating valve is closed, then open the valve of oxygen cylinder slowly, regulate the flow after the high pressure gauge shows the pressure of the oxygen cylinder.
3. No drastic shock, far away with the corrosive substance, and no oil stain.
4. The set screw of the safety valve can't be rotated at random, non-professional people are forbidden to dismount. Condition for storage Should be kept in the environment whose humidity is less than 90%, no corrosive gas and drafty. Quality guarantee period We will fix or change the oxygen inhalator within a half and a year after the day of living the company when it can't proper functioning, it should be under the condition of obeying the rule of storage and using.
Specification
Contact us if you need more details on Oxygen Humidifie. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Oxygen Inhalator、Medical Oxygen Humidifier. If these products fail to match your need, please contact us and we would like to provide relevant information.
Oxygen flowmeter with humidifier bottle is used in connection with gas outlets through quick adaptor, probe or pin index. It can be connected with adaptors of different types, such as French standard AFNOR, British standard, German standard DIN, American standard Ohmeda or Japanese standard.
Oxygen inhalator with humidifier
Usage: Medical care, hospital
Input pressure: 0-25MPa
Oulet pressure: 0-0.3 MPa
Flow: 0-15L/min
Connection: G5/8
Body material: Excellent brass
Medical Oxygen Regulator The flowmeter with humidifier is used in reducing gas pressure and adjusting the gas volume, which rescue patient and treat as oxygen therapy by hospital. Also may make using of other gas reduced pressure and the control flow. Product main feature: The product has artistic outlook, and flow control comfortable and stable. The reductor is adjustable; The structure is unique, and the performance is reliable. The stainless steel floater and the orange substrate flowmeter have a especially visual effect; The international standard connect way, is suitable for all kinds of gas bottle installation. Range of application Give oxygen for first-aid or oxygen uptake for the people who are lack of oxygen.
How to use
1. Open the valve of oxygen cylinder after connect the screw nut of air intake closely.
2. Connect the oxygen pipe to the oxygen outlet firmly.
3. Demount the humidifying cup(anti clock wise rotation), put some distilled water in (purified water or plain boiled water can also take place), the water quantity should be between the bottom and top tick mark, then tighten up the bottle cap to the humidifying cup(clockwise rotation).
4. Rotate the flow regulating valve to the rate you need (anti clockwise to up, clockwise to down, till to close), then put it to nose to use.
5. Close the valve of oxygen cylinder firstly while not using, then close the flow regulating valve until the pointer of oxygen manometer return to zero.
Attention
1. Make sure there is no ash on the connector and check the screw thread, then install the inhalator.
2. Make sure the flow meter is vertical to the floor and flow regulating valve is closed, then open the valve of oxygen cylinder slowly, regulate the flow after the high pressure gauge shows the pressure of the oxygen cylinder.
3. No drastic shock, far away with the corrosive substance, and no oil stain.
4. The set screw of the safety valve can't be rotated at random, non-professional people are forbidden to dismount. Condition for storage Should be kept in the environment whose humidity is less than 90%, no corrosive gas and drafty. Quality guarantee period We will fix or change the oxygen inhalator within a half and a year after the day of living the company when it can't proper functioning, it should be under the condition of obeying the rule of storage and using.
Specification
Specifications: | |
Item No. | CR-666 |
Configurations: | |
Safty valve | |
Alarm when leak | |
Pressure meter for air pressure | |
Flux: | 0-15L/min |
Oxygen Flow Meters with Humidifiers are made for the Hospital Central Gas Supply Systems to meet the Oxygen Supply. | |
Oxygen Flow Meters can be put into the Oxygen Outlets in the medical gas supply equipments such as Bed Head Trunking (Bed Head Units / Bed Head Panels), Ceiling Medical Pendants (Surgical Pendants, ICU Pendants, Endoscope Pendants, etc. ), Wall Exposed Medical Gas Supply Units, etc. |
Contact us if you need more details on Oxygen Humidifie. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Oxygen Inhalator、Medical Oxygen Humidifier. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Medical Plastic & Stainless Steel Product
Premium Related Products
Other Products
Hot Products
200ml + 2000ml Disposable Urine MeterUrine Drainage Bag without outlet valveOne way (1 way) All Silicone Foley CatheterOne way (1 way) Latex Foley CatheterHenso Infusion SetHenso IV CatheterHenso Hypodermic NeedleHenso Disposable Syringe with Safety Cap (Needle with protective cap)HENSO Micro Blood Collection Tubes screw capHENSO Non-Vacuum Blood TubesHENSO Vacuum Blood Collection Plain TubeHENSO PVC Feeding TubeHENSO Soft-Tip Nasal CannulaHENSO T-shaped Silicone Perforated Wound DrainHENSO Colored Guedel AirwayHENSO Disposable PVC Medical Oxygen Mask